AVKO

PRE-INSULATED PIPE SYSTEMS FOR DISTRICT HEATING NETWORKS


FOR DIRECT BURIAL
Pre-insulated piping system for CENTRALIZED DISTRICT HEATING

PRE-INSULATED VALVE

PRE-INSULATED VALVE PRE-INSULATED VALVE

 

 DN - Nominal diameter (mm)

d - Steel pipe outside diameter (mm)

D - Casing PE pipe outside diameter (mm)

D1 - Casing PE pipe outside diameter (mm)

d2 – Stem diameter (mm)

D2 - Casing PE pipe outside diameter (mm)

H – Height    (mm)

Other sizes – on request.

DN

d

D

D1 d2 D2 H

mm

mm

mm

mm

mm

mm

25

33.7

90

110

33.7

90

400

32

42.4

110

125

33.7

90

400

40

48.3

110

140

33.7

90

420

50

60.3

125

160

33.7

90

420

65

76.1

140

200

33.7

90

430

80

88.9

160

225

33.7

90

430

100

114.3

200

250

42.4

110

450

125

139.7

225

250

42.4

110

480

150

168.3

250

315

42.4

110

500

 

Raw materials

 

Steel ball valve with parameters according:

ЕN 1983 – Steel ball valves

ISO 7121 – Steel ball valves with common industrial application

With weld ends

Work temperature: from -30 ºС to +200 ºС

Work pressure: from 25 bar to 40 bar depending on the size

HDPE Casing pipe

Otside casing pipe is manufactured from high-density polyethilene with added antioxidants, UV stabilizers and carbon black.

Internal surface of PE pipes is processed with Corona treatment in order to achieve better adhesion with PUR foam.

 

Polyurethane system

AVKO jsc is using polyurethane system with foaming agent cyclopentane. The resulting PUR foam is characterized with very low heat conductivity coefficient  < 0,027 W/mK.